Products

product category

All categories

search products

1/1
Number of views:
1000
Keyword 1:
Component Tester
Keyword 2:
Frequecny ≤300kHz, LCR
Keyword 3:
Precision Type
option:

th  th  th  th  th

th

TH2827A

Precision LCR Meter
Frequency 20Hz-300kHz.
Basic Accuracy: 0.05%
AC Signal: 5mV-2V, 50uA-20mA
DC Bias: 0+/-5V, 0+/-50mA
Retail price
0.0
Yuan
Market price
0.0
Yuan
Number of views:
1000
Quantity
-
+
Stock:
0
Product description

Features

■ 4.3-inch TFT LCD display

■ Selectable Chinese and English operation interfaces

■ Maximum test frequency of 300kHz, resolution of 10mHz

■ Transformer parameter test function

■ Maximum test speed: 13ms/time

■ Automatic level control (ALC) function for V and I

■ Test signal level monitor function for V and I

■ Included interior DC bias source

■ External DC bias source of large current

■ 10-point list sweep function

■ Selectable internal resistance of 30Ω, 50Ω and 100Ω

■ Built-in comparator:10-bin sorting and bin counter

■ Internal file storage and external USB-disk file storage 

■ Test data can be saved to USB-disk directly

■ RS232C, USB, LAN, HANDLER, GPIB, DCI interface

 

Brief Introduction

■ TH2827 series is a new precision LCR meter with various functions and a higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. This instrument has a basic accuracy of 0.05%, maximum test frequency of 1MHz and resolution of 10 mHz. It is easy to operate with a 4.3-inch LCD screen as well as selectable Chinese and English operation interfaces. Integrated transformer test function greatly improve the test efficiency. The instrument is also provided with multiple interfaces which can meet various requirements of the automatic sorting test, data transmission and storage.

 

Specifications

Model TH2827A
Frequency of test signal Frequency 20Hz—300kHz
Minimum resolution 10mHz, 4-digit frequency input
Accuracy 0.01%
Display 800×RGB×480  7-inch TFT LCD display
ACLevel Voltage range of test signal 5mV—2Vrms
Minimum resolution of voltage 100μV, 3-digit input
Accuracy ALC ON 10% x set voltage + 2mV
ALC OFF 6% x set voltage + 2mV
Current range of test signal 100μA—20mA
Minimum resolution of current 1μA, 3-digit input
Accuracy ALC ON 10% x set current + 20μA
ALC OFF 6% x set voltage + 20μA
DCbias voltage source Voltage/Current range 0V— ±5V / 0mA—±50mA
Resolution 0.5mV / 5μA
Voltage accuracy 1% x set voltage + 5mV
ISO ON Be used for the bias test of inductance and transformer
AC Source impedance ISO ON 100Ω
ISO OFF 30Ω、50Ω、100Ω selectable
DCR source impedance 30Ω、50Ω、100Ω selectable
Test parameters of LCR |Z|,Y|, C, L, X, B, R, G, D, Q, θ,DCR, Vdc-Idc
Parameter display of test page One set of main/sub parameter,10-point list sweep
Test parameters of transformer DCR1(primary, 2-terminal),DCR2(secondary, 2-terminal),M (mutual inductance), N, 1/N,Phase, Lk (leakage inductance),C(primary, secondary capacitance),
Basic accuracy LCR test parameter 0.05%
N 0.1%
Calibration

Warm-up time ≥ 30 seconds;    

Environment temperature:23±5ºC;  

Signal voltage: 0.3Vrms-1Vrms;

Zeroing: After OPEN or SHORT;

Length of test cable: 0 m

Measurement time(≥10 kHz) Fast: 13 ms/time. Medium: 67 ms/time. Slow:187 ms/time. Plus the refresh time of display character
Display range ofLCR parameter Z, R , X,DCR 0.00001Ω — 99.9999MΩ
|Y|,G,B 0.00001μs — 99.9999s
C 0.00001pF —  9.99999F
L 0.00001μH —  99.9999kH
D 0.00001 —  9.99999
Q 0.00001 —  99999.9
θ(DEG) -179.999º — 179.999º
θ(RAD) -3.14159 — 3.14159
Δ% -999.999% — 999.999%
Equivalent circuit Serial, Parallel
Range mode Auto, Hold
Trigger mode Internal, Manual, External, Bus
Average times 1-255
Calibration function Open,short calibration with full frequency or dot frequency,Load
Math operation Direct reading, ΔABS, Δ%
Delay time setup 0-999, minimum resolution: 100us
Comparator 10-bin sorting, BIN1-BIN9, NG,AUX
Bin counter
PASS/FAIL on front panel,LED indication
List sweep

·201 points list sweep

·Frequency, AC voltage/current, internal/external bias voltage/ current can be swept.

·Each sweep point can be sorted  separately.

Internal nonvolatilememory 40 sets of LCRZ setting files
External USB memory GIF files. LCRZ setting files. Test data can be stored via USB memory directly.
Interface I/O interface HANDLER on rear panel
SCI USB、RS232C
PCI GPIB (optional)
NI LAN
Memory interface USB HOST (front panel)
General Specifications
Operating temperature and humidity 0℃-40℃, ≤ 90%RH
Power supply Voltage 99V-121V,198V-242V AC
Frequency 47Hz-63Hz
Consumption Max. 80 VA
Dimension(W×H×D) 280 mm × 88 mm × 370 mm(with no sheath)369 mm × 108 mm × 408 mm(with sheath)
Weight Approx. 5 kg

 

Accessary

Standard
Accessories name Model  
Transformer Test Fixture TH26038
Fixture TH26048
Short circuit TH26010 z
Kelvin test lead with box four-terminal insulation and lock TH26011AS

 

Keyword:
lcr meter
2827
2827a
th2827
We could not find any corresponding parameters, please add them to the properties table
Prev:
Next:

downloads

Name of data Download

relevant Products

Interested in this product? Please leave us a message for more information.

Username used for comment:
客户留言
Description:
验证码

Feedback

留言应用名称:
客户留言
描述:
验证码
Changzhou Tonghui Electronic Co. Ltd.   苏ICP备XXXXXX号  Powered by: www.300.cn Changzhou tha   tha   tha   tha