Products

product category

All categories

search products

1/1
Number of views:
1000
Keyword 1:
Component Tester
Keyword 2:
Frequecny 1M-10MHz, LCR
Keyword 3:
Precision Type
option:

th  th  th  th  th

th

TH2829C

Precision LCR Meter
Frequency 20Hz-1MHz.
Basic Accuracy: 0.05%
AC Signal: 5mV-10V, 50uA-100mA
DC Bias: 0+/-10V, 0+/-100mA
Graphic Sweep
Retail price
0.0
Yuan
Market price
0.0
Yuan
Number of views:
1000
Quantity
-
+
Stock:
0
Product description

Features

■ 800×RGB×480 7-inch TFT LCD display

■ Basic accuracy: 0.05%

■ Test signal frequency of 1MHz, resolution of 1mHz, 5-digit frequency input

■ Strongest signal source selection:

 10V/100mA programmable AC test level

 10V/100mA programmable DC bias supply

 10V/50mA standalone DC voltage source

 1A interior DC bias current source (optional)

 120A external bias source (optional)

■ Maximum test speed: 9ms/time

■ Simultaneous display of 4 kinds of test parameters

■ 201 -point list sweep function

■ Continuous curve scanning/graphical analysis function

■ Internal storage of 100 sets of LCRZ setting files and 10 sets of GIF image

■ GIF image and CSV data files can be saved to USB storage directly

■ HANDLER, USB, LAN, RS232C, GPIB (option), DCI interface

 

Brief Introduction

■ By dint of leading impedance measurement technology and rich R&D experience, Tonghui continuously introduces representative impedance measurement product --- TH2829 series automatic component analyzer is another excellent product we have produced.TH2829 series automatic component analyzer possesses a higher test speed, a more comprehensive analysis function and friendly human-computer interactive experience by adopting the latest high-speed processor and a new software system. Well-designed measuring circuit and optimized algorithms further enhance the test stability of low-D capacitance and high-Q inductors. The instrument is provided with 10V AC test level, 10V/100mA bias current and standalone 10V/50mA DC current, making it convenient for applying in the test of all kinds of active/ passive devices. Main/sub parameters display, enhanced display system design, 150-points list sweep and graphical analysis capabilities of multiple parameters meet the most application requirements of customers.

Thanks to the application of a new generation of processors, the instrument has a more powerful data processing capability. The test results can be easily stored in the U disk or uploaded to the upper PC or network through multiple interfaces, promoting test automation and test efficiency.

The test frequency of TH2829 series are 20Hz-300kHz, 20Hz500kHz and 20Hz-1MHz. The instrument has a test accuracy of 0.05% and highest test speed of 9ms/time. Being equipped with multiple interfaces of HANDLER, USB, LAN, RS232C, DCI, GPIB (option) as well as rich resources, the instrument will bring excellent cost performance experience for customers.

TH2829 series automatic component analyzer is completely appropriate for test requirements of all kinds of industrial and military standards.

 

Specifications

Model TH2829C
Frequency of test signal   20Hz—1MHz
Minimum resolution 1mHz, 5-digit frequency input
Accuracy 0.01%
Display 800×RGB×480  7-inch TFT LCD display
ACLevel Voltage range of test signal 5mV—10Vrms
Minimum resolution of voltage 100μV, 3-digit input
Accuracy ALC ON 10% x set voltage + 2mV
ALC OFF 6% x set voltage + 2mV
Current range of test signal 50μA—100mA
Minimum resolution of current 1μA, 3-digit input
Accuracy ALC ON 10% x set current + 20μA
ALC OFF 6% x set voltage + 20μA
DCbias voltage source Voltage/Current range 0V— ±10V / 0mA—±100mA
Resolution 0.5mV / 5μA
Voltage accuracy 1% x set voltage + 5mV
ISO ON Be used for the bias test of inductance and transformer
AC Source impedance ISO ON 100Ω
ISO OFF 30Ω、50Ω、100Ωselectable
DCR Source impedance 30Ω、50Ω、100Ωselectable
DC Independent voltage source Voltage/current range 0V— ±10V / 0mA—±50mA
Resolution 0.5mV / 5μA
Voltage accuracy 1% x set voltage + 5mV
Output resistance 100Ω
Test parameters of LCR |Z|,Y|, C, L, X, B, R, G, D, Q, θ, DCR,Vdc-Idc
Parameter display of test page Two sets of main/sub parameters, the second set can be set as ON/OFF;There can be 10 pages of list sweep and 15 points per page at most; Multiple parameters continuous sweep graphical analysis.
Basic accuracy LCR test parameter 0.05%
Calibration

Warm-up time ≥ 30 seconds;

Environment temperature: 23±5ºC;  

Signal voltage: 0.3Vrms-1Vrms

Zeroing: After OPEN or SHORT;    

Length of test cable: 0 m

Measurement time(≥10 kHz) Fast: 9 ms/time. Medium: 67 ms/time. Slow:187 ms/time. Plus the refresh time of display character
Display range ofLCR parameter Z, R ,X,DCR 0.00001Ω — 99.9999MΩ
|Y|,G,B 0.00001μs — 99.9999s
C 0.00001pF —  9.99999F
L 0.00001μH —  99.9999kH
D 0.00001 —  9.99999
Q 0.00001 —  99999.9
θ(DEG) -179.999º — 179.999º
θ(RAD) -3.14159 — 3.14159
Δ% -999.999% — 999.999%
Equivalent circuit Serial, Parallel
Range mode Auto, Hold
Trigger mode Internal, Manual, External, Bus
Average times 1-256
Calibration function Open, short calibration with full frequency or dot frequency, Load
Math operation Direct reading, ΔABS, Δ%
Delay time setup 0-999, minimum resolution: 100us
Comparator 10-bin sorting, BIN1-BIN9, NG, AUX
Bin counter
PASS/FAIL on front panel, LED indication
List sweep

·201 -point list sweep function

·List sweep of frequency, AC voltage/ current, internal/external DC bias voltage/current and independent DC source voltage can be performed on  each page. Each sweep point can be sorted separately.

Graphical analysis

·Graph scanning and analysis of frequency, AC level and DC bias can  be performed.

·Set the sweep start point, end point and each sweep point.

·Display the maximum value, minimum value and read any of the chosen sweep point

·Scanning graphs can be stored into internal or external USB memory.

Internal nonvolatilememory 100 sets of LCRZ setting files memory 201 times test results 10 sets of GIF image, CSV data files
External USB memory

·GIF image, CSV data files

·LCRZ setting files memory

·Test data can be stored via USB memory directly.

Interface 1A bias current source 1A DC bias current source (optional) can be stalled
I/O interface HANDLER on rear panel
SCI USB、RS232C
PCI GPIB(optional)
NI LAN
Memory interface USB HOST(front panel)
General Specifications
Operating temperature and humidity 0℃-40℃, ≤ 90%RH
Power supply Voltage 99V-121V, 198V-242V AC
Frequency 47Hz-63Hz
Consumption Max. 80 VA
Dimension(W×H×D) 400mm × 132mm × 385mm
Weight Approx.13 kg

 

Accessary

Standard
Accessories name Model  
Fixture TH26048
Short circuit TH26010 z
Kelvin test lead with box four-terminal insulation and lock TH26011BS z

 

Keyword:
lcr meter
2829c
2829
th2829
2829b
We could not find any corresponding parameters, please add them to the properties table
Prev:
Next:

downloads

Name of data Download

relevant Products

Interested in this product? Please leave us a message for more information.

Username used for comment:
客户留言
Description:
验证码

Feedback

留言应用名称:
客户留言
描述:
验证码
Changzhou Tonghui Electronic Co. Ltd.   苏ICP备XXXXXX号  Powered by: www.300.cn Changzhou tha   tha   tha   tha
Changzhou Tonghui Electronic Co. Ltd.   苏ICP备05016932号-1  Powered by: www.300.cn Changzhou tha   tha   tha   tha