Keyword 1:
Digit Multimeter
Keyword 2:
Keyword 3:
option:

th th   

th

TH1951 (Discontinued)

Digit Multimeter
5 1/2 Digit
Max Reading 120000
VFD Display
Retail price
0.0
Yuan
Market price
0.0
Yuan
Number of views:
1000
Quantity
-
+
Stock:
0
Product description

Features

■ TH1951 5 1/2 digit display(119,999 counts)

■ 12 different measurement capabilities: DCV/ACV, DCI/ACI,Ω2W/Ω4W,Frequency/Period, Diode Test, Continuity, dB/dBm

■ High brightness vacuum fluorescent display

■ True-rms AC voltage and current measurement, bandwidth up to 100kHz(TH1951)/300kHz(TH1961)

■ DCV measurement accuracy up to 0.0035%, resolution up to 0.1uV

■ Max. measurement rate: 1000 meas/sec

■ Equal accuracy frequency measurement up to 1.1MHz

■ Relative mode(REL) to eliminate residual reading

■ 2 W, 4W resistance measurement mode selectable

■ Built-in mX +b,%, dB, dBm etc. mathematics calculation function

■ 512 readings storage and MAX/MIN/AVER/STD statistics

■ Up to 30,000 readings storage(without statistics)

■ HI/IN/LO comparator function

■ USB, BPIB and RS-232 Interfaces provide easy system communication

■ Calibration without opening the case

■ 10 sets of multimeter setup can be stored and loaded

 

The TH1951/TH1961 5 1/2, 6 1/2 digit multimeter can test voltage/current/resistance fast and accurately. Its outstanding performance,such as max.1,200,000 counts, high reading rate1000 meas/sec as well as DC voltage accuracy of 0.0035% provides an ideal costeffective option for customer.

The concise design of front panel of TH1951/TH1961 makes it easier to locate and select the measurement function. High brightness VFD display allows the user to view clearly. Its 12 different measurement functions, including DCV/ACV, DCI/ACI, Ω 2W/Ω 4W, Frequency/Period, Diode Test, Continuity, dB/dBm, cover all basic measurement needs.

Many new technologies have been adopted in TH1951/TH1961, such as high speed low noise 26 bits A/D converter which gives the good linear and low noise performances. Fast response servo amplifier, floating power source and low offset buffer amplifier constitute front end of servo so as to remove the traditional attenuation, reduce offset drifting as well as to increase measurement rate. The SMD in the multimeter reduces the system density and volume.

TH1951/TH1961 adopts special input overload protect circuit which can stand 1500V voltage between input and ground. When overloaded, it can recover fast so as to ensure the safety and reliability of the equipment.

Standard GPIB, USB(or RS-232) interface with universal communication software is used with TH1951/TH1961 for easy TH1951/TH1961 communication, data analysis and statistics as well as construction of an automatic measurement system. The system accepts SCPI(standard commands for programmable instrument) command sets. It is compatible in communication software

 

Specifications

Test  Function
Test  Parameter DCV, ACV, DCI, ACI, Ω2W, Ω4W, FREQ, PERI DIODE, CONT
Mathematics Function mX+b, %, dB, dBm, REL
Range Auto, Manual
Display VFD
Trigger Mode INT/MAN/BUS/EXT
Programmable Time Delay 0 − 6000mS
Reading Storage and Statistics

2 to 512 readings can be stored, loaded and counted

Type of statistics: MAX, MIN, AVER, STD

Reading Hold To find out best stable reading for each data block of the given reading number according to the given accuracy.
Limitation Measurement To judge HI, IN, LO and display, with ALARM for HI/LO
Setup Storage 10 setup files can be stored and loaded
Calibration Recommend Fluke 5520A with TH1951/TH1961 Accuracy Calibration software( option )
Communication Interface SCPI command support for GPIB(optional), RS232(optional) and USB(standard) interface
Specifications
Measurement Condition
Calibration interval: one year. Operation Humidity: 18°C−28°C, ≤90%RH; When resistor range is 10M and 100M, ≤70%RH. Warming up time: 30 min. Accuracy is expressed as:  +/-(% of reading +% of range). Temperature coefficient: 0°C--18°C &  28°C--40°C, +0.1%×accuracy /°C. Following is the specification at slow mode, others please refer the operation manual .
Full Scale Reading Digits and Reading Rate (meas/sec)
Rate Slow Med Fast
TH1951  TH1961
Full Scale Reading (digits) 119,999 1,199,999 119,999 11,999
Reading Rate
(meas/sec)
DC V,DC I 4  2 16 57
AC V,AC I 3  1.5 4 25
Ω 2W 4  2 16 57
Ω 4W 3  1.5 10 33
DC V
Range Max. reading Resolution Accuracy Input impedance
TH1951 100mV 119.999 1µV 0.02+0.008 >10GΩ
1V 1.19999 10µV 0.01+0.004 >10GΩ
10V 11.9999 100µV 0.01+0.004 >10GΩ
100V 119.999 1mV 0.01+0.004 10MΩ
1000V 1010.00 10mV 0.01+0.004 10MΩ
TH1961 100mV 119.9999 0.1µV 0.0065+0.0045 >10GΩ
1V 1.199999 1µV 0.0040+0.0009 >10GΩ
10V 11.99999 10µV 0.0035+0.0005 >10GΩ
100V 119.9999 100µV 0.0045+0.0006 10MΩ
1000V 1010.000 1mV 0.0055+0.0015 10MΩ
DC I
Range Max. reading Resolution Accuracy Burden voltage
/shunt  resistor
TH1951 10mA 11.9999 0.1µA 0.05+0.008 <0.15V/10.1Ω
100mA 119.999 1µA 0.05+0.004 <1.5V/10.1Ω
1A 1.19999 10µA 0.10+0.004 <0.3V/0.1Ω
10A 11.9999 100µA 0.25+0.004 <0.15V/10mΩ
TH1961 10mA 11.99999 10nA 0.05+0.004 <0.15V/10.1Ω
100mA 119.9999 0.1µA 0.05+0.004 <1.5V/10.1Ω
1A 1.199999 1µA 0.08+0.004 <0.3V/0.1Ω
10A 11.99999 10µA 0.25+0.004 <0.15V/10mΩ
AC V
Range 100mV 1V 10V 100V 750V
TH1951 Max. reading 119.999 1.19999 11.9999 119.999 757.5
Resolution 1µV 10µV 100µV 1mV 10mV
10~20 Hz 1.5+0.1
20~50 Hz 0.5+0.1
50Hz~20 kHz 0.1+0.1
20~50 kHz 0.3+0.15 0.3+0.1
50~100 kHz 1+0.15 1+0.1
TH1961 Max. reading 119.9999 1.199999 11.99999 119.9999 757.50
Resolution 0.1µV 1µV 10µV 100µV 1mV
10~20 Hz 1.50+0.20
20~50 Hz 0.50+0.10
50Hz~100Hz 0.10+0.03
100~20 kHz 0.05+0.03 0.08+0.03
20~50 kHz 0.15+0.05 0.11+0.05 0.18+0.05 ------
50~100kHz 0.60+0.08 ------
100~300kHz                 4.00+0.05 ------ ------
  Ω2W/Ω4W
Range Max. reading Resolution Measurement
current
Accuracy
TH1951 100 Ω 119.999 1mΩ 1 mA 0.05+0.008
1 kΩ 1.19999 10mΩ 1 mA 0.03+0.004
10 kΩ 11.9999 100mΩ 100μA 0.03+0.004
100 kΩ 119.999 10μA 0.03+0.004
1 MΩ 1.19999 10Ω 10μA 0.03+0.004
10 MΩ 11.9999 100Ω 7.0×Rx
/(10M+Rx)
0.1+0.004
100 MΩ 119.999 1KΩ 7.0×Rx
/(10M+Rx)
0.5+0.008
TH1961 100 Ω 119.9999 100µΩ 1 mA 0.010+0.004
1 kΩ 1.199999 1mΩ 1 mA 0.010+0.001
10 kΩ 11.99999 10mΩ 100μA 0.010+0.001
100 kΩ 119.9999 100m Ω 10μA 0.010+0.001
1 MΩ 1.199999 10μA 0.010+0.001
10 MΩ 11.99999 10Ω 7.0×Rx
/(10M+Rx)
0.040+0.001
100 MΩ 119.9999 100Ω 7.0×Rx
/(10M+Rx)
0.800+0.010
Frequency
Range Max. reading Resolution Accuracy Sensitivity
(sine wave)
TH1951 5Hz~10 Hz 9.99999 10μHz 0.05+0.1 200mV rms
10Hz~100Hz 99.9999 100μHz 0.01+0.01 40mV rms
100Hz~100 kHz 999.999 1mHz 0.005+0.002 40mV rms
100k~1.1MHz 1099.99 1Hz 0.005+0.002 100mV rms
TH1961 5Hz~10 Hz 9.999999 1μHz 0.05+0.1 200mV rms
10Hz~100Hz 99.99999 10μHz 0.01+0.01 40mV rms
100Hz~100 kHz 999.9999 10mHz 0.005+0.002 40mV rms
100k~1.1MHz 1099.999 0.1Hz 0.005+0.002 100mV rms

 

Accessary

Standard
Accessories name Model  
Multimeter Test Cable TH26036

 

Optional
Accessories name Model  
Four Terminal Test Line TH26039
Keyword:
Digit Multimeter
Digit Multimeter
dmm
1951
5 DIGIT
We could not find any corresponding parameters, please add them to the properties table
Prev:
Next:

downloads

Name of data Download

relevant Products

Interested in this product? Please leave us a message for more information.

Username used for comment:
客户留言
Description:
验证码

Feedback

留言应用名称:
客户留言
描述:
验证码
Changzhou Tonghui Electronic Co. Ltd.   苏ICP备XXXXXX号  Powered by: www.300.cn Changzhou tha   tha   tha   tha
Changzhou Tonghui Electronic Co. Ltd.   苏ICP备05016932号-1  Powered by: www.300.cn Changzhou tha   tha   tha   tha