TH1991B

Source Measurement Unit
DC Voltage/Current: +/-210V, +/-3A
Channel 1
5.5 Digit
Retail price
0.0
Yuan
Market price
0.0
Yuan
Number of views:
1000
Quantity
-
+
Stock:
0
Product description

Features

• 7-inch capacitive touch screen, resolution 800×480

• Linux operating system

• Four-quadrant precision power output and measurement

• Single/dual channel output and measurement

• Up to ±210V DC voltage, ±3A DC current/±10.5A pulse

• 10fA/100nV minimum measurement resolution (6 1/2 digits)

• 10fA/100nV minimum supply resolution (6 1/2 digits)

• Up to 1,000,000 dots/sec sampling rate

• Arbitrary waveform generation

• List scan function (minimum 1μs interval)

• Direct generation of I/V curves of diodes, triodes, MOS tubes and IGBTs

 

Brief Introduction

TH1991/TH1992 series precision source/measure units can output and measure voltage and current at the same time. The instrument integrates the functions of current source, voltage source, voltmeter and ammeter, and each function can be switched arbitrarily.  

TH1991/TH1992 series precision source/measure units can output up to ±210V DC voltage, ±3A DC current and ±10.5A pulse current, minimum 10fA/100nV power supply and measurement resolution, support high-speed sampling, and can generate arbitrary waveforms.  

TH1991/TH1992 series precision source/measure unit series adopts 7-inch capacitive touch screen, with Linux operating system as the bottom layer, interactive graphical user interface and various display modes, and built-in diodes, triodes, MOS tubes and IGBTs and other devices. The I/V curve scanning function can complete the IV function test without connecting to the host computer, which can significantly improve the test efficiency.                                                                         

The TH1991/TH1992 series of precision source/measure units with comprehensive and integrated power and measurement functions are ideal for testing semiconductors, active/passive devices, and a variety of other devices and materials.     

The TH1991/TH1992 series of precision source/measure units are widely used in R&D and educational applications, industrial development, testing and manufacturing.           

 

Application

• Semiconductor, discrete and passive component testing

Diodes, Laser Diodes, LEDs

Photodetectors, Sensors

Field effect transistor, triode

ICs (ICs, RFICs, MMICs)

Resistors, rheostats, thermistors, switches

• Precision electronics and green energy device testing

PV

power semiconductor

Battery

car

medical instrument

Power and DC Bias Sources for Board Level Testing

• Research and Education

new material research

Nanodevice properties

giant magnetoresistance

organic equipment

Any precision I/V source or measure       

 

Specifications

Model TH1991C TH1991B TH1991A TH1991 TH1992A TH1992
Display
Display 7-inch capacitive touch screen, resolution 800×480
Key Parameters
Channel 1 1 1 1 2 2
Max Output Voltage ±63V ±210V ±210V ±210V ±210V ±210V
Current DC ±1.515A ±3.03A ±3.03A ±3.03A ±3.03A ±3.03A
Impulse ------ ------ ±10.5A ±10.5A ±10.5A ±10.5A
Power Source Max Digits Digits 5 1/2 5 1/2 5 1/2 6 1/2 5 1/2 6 1/2
Min Resolution Voltage 1μV 1μV 1μV 100nV 1μV 100nV
Current 1pA 100fA 1pA 10fA 1pA 10fA
Measurement Max Digits Digits 6 1/2 6 1/2 6 1/2 6 1/2 6 1/2 6 1/2
Min Resolution Voltage 100nV 100nV 100nV 100nV 100nV 100nV
Current 100fA 10fA 100fA 10fA 100fA 10fA
Voltage Range 200mV-60V 200mV-200V
Min Time Interval 50μs 20μs 10μs 1μs 10μs 1μs
Voltage Source (Accuracy: Reading % + Bias, Noise: peak-to-peak (0.1Hz-10Hz))
Range ±200mV Programming Resolution 1μV 1μV 1μV 100nV 1μV 100nV
Accuracy ±(0.015% + 225μV)
Nosie ≤10μV
Max Voltage ±210 mV
±2V Programming Resolution 10μV 10μV 10μV 1μV 10μV 1μV
Accuracy ±(0.02% + 350μV)
Nosie ≤20μV
Max Voltage ±2.1V
±20V Programming Resolution 100μV 100μV 100μV 10μV 100μV 10μV
Accuracy ±(0.015% + 5mV)
Nosie ≤200μV
Max Voltage ±21V
±200V Programming Resolution 1mV 1mV 1mV 100μV 1mV 100μV
Accuracy ±(0.015% + 50mV)
Nosie ≤2mV
Max Voltage ±210V
Voltage Measurement (Accuracy: Reding %+ Bias)
Range ±200mV Measurement Resolution 100nV
Accuracy ±(0.015% + 225μV)
±2V Measurement Resolution 1μV
Accuracy ±(0.02% + 350μV)
  Measurement Resolution 10μV
±20V Accuracy ±(0.015% + 5mV)
±200V Measurement Resolution 100μV
Accuracy ±(0.015% + 50mV)
Current Source (Accuracy: Reading % + Bias, Noise: peak-to-peak (0.1Hz-10Hz))
Range ±10nA Programming Resolution 1pA 100fA 1pA 10fA 1pA 10fA
Accuracy ±(0.10% + 50pA)
Nosie ≤1pA
Max Current ±10.5nA
±100nA Programming Resolution 1pA 1pA 1pA 100fA 1pA 100fA
Accuracy ±(0.06% + 100pA)
Nosie ≤2pA
Max Current ±105 nA
±1μA Programming Resolution 10pA 10pA 10pA 1pA 10pA 1pA
Accuracy ±(0.025% + 500pA)
Nosie ≤25pA
Max Current ±1.05μA
±10μA Programming Resolution 100pA 100pA 100pA 10pA 100pA 10pA
Accuracy ±(0.025% + 1.5nA)
Nosie ≤60pA
Max Current ±10.5μA
±100μA Programming Resolution 1nA 1nA 1nA 100pA 1nA 100pA
Accuracy ±(0.02% + 25nA)
Nosie ≤2nA
Max Current ±105μA
±1mA Programming Resolution 10nA 10nA 10nA 1nA 10nA 1nA
Accuracy ±(0.02% + 200nA)
Nosie ≤6nA
Max Current ±1.05mA
±10mA Programming Resolution 100nA 100nA 100nA 10nA 100nA 10nA
Accuracy ±(0.02% + 2.5μA)
Nosie ≤200nA
Max Current ±10.5mA
±100mA Programming Resolution 1μA 1μA 1μA 100nA 1μA 100nA
Accuracy ±(0.02% + 20μA)
Nosie ≤600nA
Max Current ±105mA
±1A Programming Resolution 10μA 10μA 10μA 1μA 10μA 1μA
Accuracy ±(0.03% + 1.5mA)
Nosie ≤70μA
Max Current ±1.05A
±1.5A Programming Resolution 10μA 10μA 10μA 1μA 10μA 1μA
Accuracy ±(0.05% + 3.5mA)
Nosie ≤100μA
Max Current ±1.515A
±3A Programming Resolution 100μA 100μA 100μA 10μA 100μA 10μA
Accuracy ±(0.4% + 7mA)
Nosie ≤120μA
Max Current ±3.03A
±10A (Impulse) Programming Resolution 100μA 100μA 100μA 10μA 100μA 10μA
Accuracy ±(0.4% + 25mA)
Nosie ------
Max Current ±10.5 A
Current Measurement
Range ±10 nA Measurement Resolution 10fA
Accuracy ±(0.10 % + 50 pA)
±100nA Measurement Resolution 100fA
Accuracy ±(0.06% + 100pA)
±1μA Measurement Resolution 1pA
Accuracy ±(0.025% + 500pA)
±10μA Measurement Resolution 10pA
Accuracy ±(0.025% + 1.5nA)
±100μA Measurement Resolution 100pA
Accuracy ±(0.02% + 25nA)
±1mA Measurement Resolution 1nA
Accuracy ±(0.02% + 200nA)
±10mA Measurement Resolution 10nA
Accuracy ±(0.02% + 2.5μA)
±100mA Measurement Resolution 100nA
Accuracy ±(0.02% + 20μA)
±1A Measurement Resolution 1μA
Accuracy ±(0.03% + 1.5mA)
±1.5A Measurement Resolution 1μA
Accuracy ±(0.05% + 3.5mA)
±3A Measurement Resolution 10μA
Accuracy ±(0.4% + 7mA)
±10A Measurement Resolution 10μA
Accuracy ±(0.4% + 25mA)
Pulse source (pulse width refers to the time from 10% rising edge to 90% falling edge, base level: pulse low level, peak level: pulse high level)
Minimum programmable pulse width 50μs
Pulse width programming resolution 1μs
Max Voltage of DC or Impulse 210V Max Peak Current 0.105A
Max Base Current 0.105A
Impulse Width 50μs - 99999.9s
Max Duty Cycle 99.9999%
21V Max Peak Current 1.515A
Max Base Current 1.515A
Impulse Width 50μs - 99999.9s
Max Duty Cycle 99.9999%
6V Max Peak Current 3.03A
Max Base Current 3.03A
Impulse Width 50μs - 99999.9s
Max Duty Cycle 99.9999%
Impulse Only 200V Max Peak Current 1.515A
Max Base Current 50mA
Impulse Width 50μs - 2.5ms
Max Duty Cycle 2.5%
180V Max Peak Current 1.05A
Max Base Current 50mA
Impulse Width 50μs - 10ms
Max Duty Cycle 2.5%
6V Max Peak Current 10.5A
Max Base Current 0.5A
Impulse Width 50μs - 1ms
Max Duty Cycle 2.5%
Resistance Measurement (Auto resistance measurement mode, 4-wire, 2V range)
Range Resolution 1μΩ
Test Current 1A
Current Range 1A
Total Tolerance 0.2% + 0.00035Ω
20Ω Resolution 10μΩ
Test Current 100mA
Current Range 100mA
Total Tolerance 0.06% + 0.0035Ω
200Ω Resolution 100μΩ
Test Current 10mA
Current Range 10mA
Total Tolerance 0.065% + 0.035Ω
2kΩ Resolution 1mΩ
Test Current 1mA
Current Range 1mA
Total Tolerance 0.06% + 0.35Ω
20kΩ Resolution 10mΩ
Test Current 100μA
Current Range 100μA
Total Tolerance 0.065% + 3.5Ω
200kΩ Resolution 100mΩ
Test Current 10μA
Current Range 10μA
Total Tolerance 0.06% + 35Ω
2MΩ Resolution
Test Current 1μA
Current Range 1μA
Total Tolerance 0.095% + 350Ω
20MΩ Resolution 10Ω
Test Current 100nA
Current Range 100nA
Total Tolerance 0.18% + 3.5kΩ
200MΩ Resolution 10Ω
Test Current 10nA
Current Range 10nA
Total Tolerance 1.08% + 35kΩ
Interface RS232C, USB HOST, USB DEVICE, LAN, HANDLER
Environment and Temperature
Operation temperature and humidity range 23°C±5°C
Storage temperature and humidity range 23°C±5°C
Accuracy guarantees temperature and humidity 23°C±5°C
Preheat time 60 Minutes
Ambient temperature change 30% to 80% RH
Calibration cycle One year
General Parameter
Power Supply 90 V to 264 V, 47Hz to 63Hz, 250 VA maximum
Power 31.8W
Shelf Size 125mmx132mmx480mm
Dimensions 236mmx154mmx526mm
Weight About 6kg (Single Channel) / 7.5kg (Dual Channel)

 

Accessary

Standard
Accessories name Model  
     

 

Optional
Accessories name Model  
Keyword:
th1991
1991
smu
Source Measurement Unit
1991B
We could not find any corresponding parameters, please add them to the properties table
Prev:
Next:

downloads

Name of data Download

relevant Products

Interested in this product? Please leave us a message for more information.

Username used for comment:
客户留言
Description:
验证码

Feedback

留言应用名称:
客户留言
描述:
验证码
Changzhou Tonghui Electronic Co. Ltd.   苏ICP备XXXXXX号  Powered by: www.300.cn Changzhou tha   tha   tha   tha
Changzhou Tonghui Electronic Co. Ltd.   苏ICP备05016932号-1  Powered by: www.300.cn Changzhou tha   tha   tha   tha