■ 24-bit color 4.3-inch color LCD display
■ LCD resolution 480*272
■ Numeric keypad operation
■ Low ripple and low noise
■ Intelligent fan control to save energy and reduce noise
■ Software monitoring via computer
■ Editable voltage and current output waveform with time(resolution 1ms) (LBT mode)
■ The power output can be turned on and off by an external signal
■ The knob can be used to coarsely adjust and fine tune the voltage and current values.
■ High accuracy and resolution: 0.1mV/0.01mA
■ Timing output time can be set (0.01-9999.99S)
■ Screen information can be stored in the USB flash drive
■ Chinese and English user interface
■ Flexible and convenient file operating system
■ Built-in 5 1/2 digital milliohm meter
■ Automatic upgrade of instrument operating software via USB HOST
■ Handler interface for online operations
■ RS232, USB HOST, USB Device, GPIB can easily realize the data communication with PC and remote control of the instrument
■ Comes with hardware OVP, OCP protection(OCP is software protection)
■ Front panel and rear panel with output and sampling terminals,voltage and resistance measuring terminal
■ Support standard SCPI and MODBUS communication protocols
■ R & D and design verification common test
■ Production line table routine testing and maintenance
■ Automated device integration testing
■ Solar photovoltaic simulation test
■ New power car simulation test
■ Teaching laboratory
Model | TH6511 | TH6512 | TH6513 | |
Rated Output | Voltage | 0-20V | 0-32V | 0-72V |
Current | 0-10A | 0-6A | 0-3A | |
Power | 200W | 192W | 216W | |
Load Regulation | Voltage | ≤0.01%+2mV | ||
Current | ≤0.05%+1.5mA | |||
Power Regulation | Voltage | ≤0.01%+1mV | ||
Current | ≤0.05%+1mA | |||
Set Value Resolution | Voltage | 1mV | ||
Current | 0.1mA | |||
Read-back Resolution | Voltage | 0.1mV | ||
Current | 0.01mA | |||
Year Set Accuracy (25℃±5℃) |
Voltage | ≤0.03%+3mV | ||
Current | ≤0.05%+2mA | |||
Year Read-back Accuracy (25℃±5℃) |
Voltage | ≤0.02%+3mV | ||
Current | ≤0.05%+2.5mA | |||
Ripple and Noise (20Hz-20MHz) |
Differential Mode Voltage | ≤4mVp-p and 1mVrms | ||
Differential Mode Current | <4mArms | |||
Dynamic Recovery Time (50%-100% LOAD) Restore Time within 75mv |
<200us | |||
Rise Time | 10%-90% | <20ms | ||
Fall Time | 90%-10% | <200 ms | <250 ms | <150 ms |
Overvoltage Protection | Range (Typical) | 1-19V | 1-31V | 1-71V |
Accuracy (typical) | ± (set value *0.5%+0.5V) | |||
Response Time (typical) | <10ms | |||
DVM(DC) | Display Value Accuracy | ±0.02%+10mv | ||
Display Resolution | 0.1mv | |||
Input Differential Mode Voltage Range |
0-40Vpk | |||
Input Common Mode Voltage Range |
0-30Vpk |
Standard | ||||||
Accessories name | Model | |||||
Test Cable with both ends | TH26004C | ![]() |
Optional | ||||||
Accessories name | Model | |||||
High Current Test Cable | TH26035D | |||||
High Current Test Cable | TH26035E |
Name of data | Download |