■ 7-inch TFT LCD display with a resolution of 800×RGB×480
■ Frequency up to 1MHz, resolution: 0.5mHz
■ Signal level: 5mV-2Vrms, optional (2Vrms-10Vrms)
■ Built-in 0-100mA/0-10V bias power supply, optional 1A/2A bias current source
■ Up to 75 times / sec test speed
■ Diode forward and reverse characteristic detection
■ Improved high turns ratio and weakly coupled transformer test capability
■ Improved DCR testing capabilities
■ Single screen can accommodate all scan test results
■ Time stamping system: memory file setting, calibration deviation and deduction time
■ Sort the selected scanning parameters
■ Self-test scanning fixture relays
■ Flexible deviation deduction method
■ Multiple handling ways for FAIL cases
■ Single parameter test cycle to test independent windings
■ Increased security: administrator and operator passwords
■ Built-in statistical analysis capabilities: Cpk, Cp, Ck, etc.
■ Bar-code reading function can be used to select a setting file or to manage the type of test products
■ Optional PC-level instrument test setup file programming capability
■ Online upgrade mode: USBHOST or RS232
■ Support multiple instrument networking through LAN interface
■ Storage: Internal: 100 groups of settings file to save U disk: 500 groups of configuration files, CSV format test data, GIF format images
■ Switching transformer scanning test, comprehensive characteristics analysis.
■ Network transformer scanning test, comprehensive characteristics analysis
■ Discrete passive components (L, R, C) multi-channel scanning test
■ Relay drive line package, contact resistance multi-channel scanning test
■ Multi-channel DC resistance DCR scanning test
■ Comprehensive test analysis of multiple passive components in impedance network
Specification
Model | TH2829AX | TH2829CX |
Test Pin(PIN) | 20 | |
Test Frequency | 20Hz — 200kHz | 20Hz — 1MHz |
Display | 800×RGB×480 7 inch TFT LCD display | |
LCR Function | option | |
Transformer test parameters | Turn Ratio, Turns, Phase, L, C, Lk, Q, ACR, DCR, Balance, Pin Short, Diode P/N | |
LCR Test Parameters | |Z|,Y|, C, L, X, B, R, G, D, Q, θ, DCR, Turn-Ratio, Phase, Lk | |
Basic Test Accuracy | LCRZ 0.05% | |
DCR, Turn Ratio 0.1% | ||
Signal Source Output Impedance | 30Ω, 50Ω, 100Ω | |
Test Speed (ms/times) | 13ms, 90 ms, 370 ms | |
AC Signal Level | 5mVrms — 2Vrms(transformer test, can be customized to 10Vrms), 5mVrms — 10Vrms(LCR function);50μArms — 100mArms | |
DC Bias Voltage Source | 0V to +/-10V, 0mA to +/-100mA | |
DC Bias Current Source | 0 — ±1A option(option TH2901) / 0 — ±2A option(option TH2902) | |
DC Constant Current Source | 0mA – ±120mA for diode forward characteristic test | |
Diode Test | forward test voltage 0-4.0000V | |
Reverse test current 0-99.999mA | ||
Comparator | 10 bins, PASS/FAIL indication, file counting function | |
Storage | Internal: 100 sets of configuration file;U disk: 500 sets of configuration files, CSV format test data, GIF format images |
Standard | ||||||
Accessories name | Model | |||||
Test line at both ends | TH26004B | |||||
Manual transformer scan test fixture | TH1901B | |||||
Foot switch | TH1801-001 | |||||
Transformer test control cable (36 cores) (2H/57S-3036*2/L 1800) | TH26016 | |||||
Kelvin test lead with box four-terminal insulation and lock | TH26011AS |
Optional | ||||||
Accessories name | Model | |||||
Pneumatic transformer scanning test fixture | TH1901A | |||||
Manual transformer scan test fixture | TH1901C |